LMC-SSD: DC Shunt Motor Soft-Starts with Speed Selection
Single Direction - Microprocessor Logic – IGBT Power Semiconductor
Solid-State Soft-Starts with Setable Speed Targets for any Application Speed Range
Operating Characteristics |
Motor Protection Features |
Operating Voltage: 230 Volts DC |
Minimum Field Current |
No Special Control Voltage Required |
Maximum Field Current |
Horsepower Range: 5 to 30 |
Armature Average Current |
Maximum Power: 21kw |
Armature Peak Current Limit |
Maximum Armature Current: 200 amps |
Over Temperature Limit |
Maximum Field Current: 10 amps. |
In-rush Current Limit |
Maximum Voltage: 320 volts DC |
|
Minimum Voltage: 100 volts DC |
Model A64295, Soft-Start with Speed Selection
Setable Ramp Time: 1 to 60 seconds.
Target-Speeds can be set: below base speed - at base speed - above base speed.
Target-Speed Control Options:
The target-speed input read at startup is followed. The target-speed cannot be changed during operation.
Stopping: The motor will coast to a stop when the target-speed input is switched off.
Model A64295/OV, Soft-Start with Variable Speed & Overhauling Braking
Setable Ramp Time: 1 to 60 seconds.
Target-Speeds can be set: below base speed - at base speed - above base speed.
Target-Speed Control Options:
The target-speed can be changed during operation.
A voltage dump IGBT is installed to dump braking energy into an external resistor. This feature allows:
Stopping: The motor will coast to a stop from base speed when the target-speed input is switched off.
Maximum dump current: 100 amps -- Recommended dump resistor value: 4 ohms.
Part A62499, Hand-Held Data Terminal
The data terminal is used to customize performance. The terminal menus provide rapid access for setting and checking operating parameters, status, faults and diagnostics.
Part A63893-16V, Optional Remote-Mount Operator Display
4X20 LCD display reports operating conditions and fault status. Order required cable A62811-2.10.
Optional Velocity Readout
A velocity encoder input is standard; with an optional user-installed encoder connected, the motor speed can be displayed.Order Writing Data
A64295 |
Soft-Start with Speed Selection, order required cable A64356-2.10. |
A64295/OV |
Soft-Start with Overhauling Braking, order required cable A64356-2.10. |
A64356-2.10 |
P1 Input Cable, for On/Off Switch and Speed Inputs (length 2.10M) One required. |
A62499 |
Data Terminal, Cable & Case -- One required for one or many soft-start units. |
Order Options |
Technical Information |
||
A63893-16V |
Operator Display, Remote Mount, |
Drawing A64398: |
Physical size and weight. |
Drawing A64399: |
Basic wiring diagram. |
||
A62811-2.10 |
Operator Display Cable (length 2.10M). |
Drawing A64370: |
Detailed system diagram |