Mining Vehicle Traction Controls
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Model |
Voltage |
Continuous |
D.C. |
Motor |
Braking |
LMC-MI-1000 |
300V |
140 amps |
190 amps |
250 amps |
250 amps |
LMC-MI-1010 |
300V |
200 amps |
240 amps |
300 amps |
250 amps |
LMC-MI-1030 |
300V |
300 amps |
350 amps |
450 amps |
350 amps |
LMC-MI-1035 |
300V |
330 amps |
400 amps |
550 amps |
350 amps |
LMC-MI-1020T |
300V |
275 amps |
350 amps |
400 amps |
500 amps |
LMC-MI-1040T |
300V |
350 amps |
480 amps |
600 amps |
500 amps |
LMC-MI-1060T |
300V |
550 amps |
625 amps |
800 amps |
700 amps |
LMC-MI-1070T |
300V |
660 amps |
720 amps |
1100 amps |
700 amps |
LMC-MIC-1010 |
300V |
200 amps |
240 amps |
300 amps |
250 amps |
LMC-MIC-1040ST |
300V |
200 amps |
300 amps |
400 amps |
400 amps |
|
|
Motor Type: |
Series Wound |
Control Range: |
0 to 100%, Plus Optional Bypass |
Logic Type: |
Micro Controller |
Operating Frequency: |
2kHz - 10kHz |
Supply Voltages: 300 Volts |
|
Safety Circuits: |
|
|
|
|
Controlled Plug Braking: Programmable from 1% to 15% pulse rate. |
|
Current Limits: D.C. Current Limit - Programmable + 0%, -25%. |
|
|
|
|
|
Temperature Protection: |
|
Arcless Switching of the Contactors. |
|
|
|
Stored Operational Fault Status: Requires hand-held data terminal to access. |
|
Storage Temperature |
-40 C to +80 C |
Operating Ambient |
-30 C to +50 C |
Shock Maximum: |
30m/sec.sec for 10ms. |
Vibration Maximum: |
10m/sec.sec at 40hz |
LMC Motor Controls Optional Software Features |
|||
Feature |
Description |
||
LMC-1 |
Two Locomotive Tandem Operation |
||
LMC-2 |
Two Locomotive Tandem Operation Via Radio Modems, All Locomotive Functions & Trackside Radio Interface. |
||
LMC-3 |
Overspeed Alarm* |
||
LMC-4 |
Overspeed Control* |
||
LMC-5 |
Acceleration Wheel-Spin Control** |
||
LMC-6 |
Anti-Lock Braking** |
||
LMC-7 |
Battery Charge Status |
||
LMC-8 |
Low Supply Voltage Alarm |
||
LMC-9 |
Motor-Current Differential Alarm |
||
LMC-10 |
Deadman-Switch Check Circuit |
||
LMC-11 |
Anti Motor Stall* |
||
LMC-12 |
Operator Display Software |
||
LMC-13 |
Velocity Feed Back Counter |
||
LMC-14 |
Closed-Loop Speed Control |
||
LMC-15 |
Trolley/Battery Combination Software |
||
* Requires installation of one velocity feedback counter - Feature 13. |
|||
** Requires installation of two velocity feedback counters, one on each motor axle. |
|||
NOTE: Some options are mutually exclusive. |
|||